Products - 2900

The 2900

  • 2" water conditioning control
  • Incorporates 2 time-tested hydraulically balanced pistons to independently pilot service flow and regeneration.
  • Brings great performance and versatility to commercial /industrial applications.
  • Suitable for use with single or multiple tank systems.
  • Backwashes tanks up to 30" diameter.
  • Continuous flow rate is 106 gpm @15 psi drop.
  • Available with 7 or 12-day timer or meter to control regeneration.
  • Solid lead free brass valve body.

Specifications and Performance:

Valve MaterialInlet/OutletCycles Lead Free Brass2"" NPT (female)5
Flow Rate (50 psi inlet)   Continuous (15 psi drop)   Peak (25 psi drop)CvMaximum Backwash (25 psi drop) Valve Alone          System106 gpm               84 gpm140 gpm              105 gpm27.525 gpm                22 gpm
Regeneration:Downflow/UpflowAdjustableTime Available YesYes164 minutes
Meter Accuracy Range  Meter Capacity Range   1" 3-150 gpm +/- 5%Standard: 1,250-21,250 galsExtended: 6,250-106,250 gals.
Dimensions:  Distributor Pilot  Drain Line  Brine Line  Mounting Base  Height (from top of tank) 1-1.5" Pipe I.D.3/4"  NPT (male)3/8" or 1/2" compression4"-8 UN12" 
Tank Application - can regenerate/backwash the following:  Water Softener  Iron Filter  Sediment Filter  Carbon Filter  Neutralizing Filter 14"-30" diameter14"-21" diameter14"-21" diameter14"-21" diameter14"-21" diameter
Electrical RatingPressureTemperature 24v, 110v, 220v-50Hz, 60HzHydrostatic: 300 psiWorking: 25-125 psi34-110 F
Cycles:1. Backwash (Upflow)2. Brine & Slow Rinse (Downflow)3. Rapid Rinse (Downflow)4. Brine Tank Refill5. Service (Downflow) Typical Time:10 minutes60 minutes10 minutes12 minutes
Options:Backwash filterHot waterMeter initiated regenerationManual operationService valve operator No hard water bypass pistonElectronic timerEnvironmental coverNickel Plating